Line Model Specifications | ||||
Model | IVPA3524 | IVPA5048 | IVPA7548 | IVPA10048 |
Rated Output Power (A) | 3500VA | 5000VA | 7500VA | 10000VA |
Rated Output Power (W) | 2800W | 4000W | 6000W | 8000W |
Norminal DC Input Voltage | 24V | 48V | 48V | 48V |
Input Voltage Waveform | Sinusoidal (Utility or generator) | |||
Terminal Connection | L-N | HOT1-HOT2 | ||
Nominal Input Voltage | 120Vac | 220Vac | ||
Low Line Disconnect | 90±3Vac(UPS) 80±3Vac (APL) | 170±7Vac(UPS) 90±7Vac (APL) | ||
Low Line Re-connect AC Input Range | 95±3Vac(UPS) 85±3Vac (APL) | 180±7Vac(UPS) 100±7Vac (APL) | ||
High Line Disconnect | 140±3Vac | 280±7Vac | ||
High Line Re-connect | 135±3Vac | 270±7Vac | ||
Max AC Input Voltage | 140Vms | 280Vms | ||
Nominal Input Frequency | 50Hz/60Hz | |||
Low Line Frequency Disconnect | 40±1Hz | |||
Low Line Frequency Re-connect | 42±1Hz | |||
High Line Frequency Disconnect | 65±1Hz | |||
High Line Frequency Re-connect | 63±1Hz | |||
Output Voltage Waveform | Synchronize with input voltage | |||
Over-Load Protection (SMPS load) | Overcurrent protector | Air switch protection | Overcurrent protector | Air switch protection |
Output Short Circuit Protection | Overcurrent protector | Air switch protection | Overcurrent protector | Air switch protection |
Efficiency (Line mode) | 95% | |||
Transfer Time (AC to DC) | 15ms (typical value) | |||
Transfer Time (DC to AC) | 15ms (typical value)/30ms (special value) | |||
Pass Through Without Battery | No | |||
Overcurrent Protector (grid) | 50A | 63A | 63A | 63A |
Utility Charge Mode Specifications | ||||
Input Voltage Range | 80-140Vac | 90-280Vac | ||
Nominal Output Voltage | Depends on The Battery Types | |||
Max Charge Current | 40A | 50A | 60A | 80A |
Charge Current Regulation | 0-40A | 0-50A | 0-60A | 0-80A |
Battery Initial Voltage | Circuit Breaker | |||
Charger Short Circuit | 50A | 63A | 63A | 63A |
Breaker Size | Dependent on Battery Type or Self-defined | |||
Over Charge Protection | YES | |||
Solar Charging & Utility Charging (MPPT built-in controller is optional) | ||||
Max PV Open Circuit Voltage | 145Vdc | 196Vdc | 195Vdc | 195Vdc |
PV Voltage Working Range | 30~145Vdc | 60~195Vdc | 60~195Vdc | 60~195Vdc |
Max Input Power | 2200W | 6600W | 6600W | 6600W |
Max Solar Charging Current | 80A | 120A | 120A | 120A |
Max Charging Current (Utility+Solar) | 120A | 170A | 180A | 200A |
Charging Algorithm | ||||
Charging Way | Three Phases: Boost CC (constant current level) -- Boost CV (constant voltage level) -- Float (constant pressure level) |
|||
Charging Stage Transition Definitions | (1) Boost CC Stage: If A/C input is appliled, the charger will run at full current in CC mode until the charger reaches the boost voltage. (2) Boost CV Stage: the charger will keep the boost voltage in Boost CV mode until the T1 timer has run out. Then drop the voltage down to the float voltage, when the charging current is lower than 20% setting value. (3) Float Stage: In float mode, the voltage will stay at the float voltage. If the A/C is reconnected or the battery voltage drops belows 24Vdc/48Vdc, the charger will reset the cycle above. |
|||
Battery Type Setting | Battery Type | Boost CC, CV | Float | |
24/48 | 24/48 | |||
AGM | 28.8/57.6 | 27.2/54.4 | ||
Flooded | 29.2/58.4 | 27.6/55.2 | ||
Self Defined | Adjustable, up tp 31.5/61.0 | |||
Inverter Mode Specifications | ||||
Model | IVPA3525 | IVPA5048 | IVPA7548 | IVPA10048 |
Output Voltage Waveform | Pure Sine Wave | |||
Nominal Output Voltage | 110/120/127Vac±5% (L-N) | 220/240Vac±5% (HOT1-HOT2) | ||
Split-Phase Output Voltage | / | 110/120Vac±5% (HOT1-N or HOT2-N) | ||
Nominal Output Frequency (Hz) | 50±0.3Hz/60±0.3Hz (adjustable) | |||
Output Voltage Regulation | ±5% rms | |||
Peak Efficiency | 90% | |||
Over-Load Protection (SMPS load) | 5s @≥150% load; 10s @ 105%-150% load | |||
Surge Rating | 2 times rated overload power 5S | |||
Capable of Starting Electric | YES | |||
Output Short Circuit Protection | YES | |||
Norminal DC Input Voltage | 24V | 48V | ||
Min DC Starting Voltage | 23V | 46V | ||
Battery Low Voltage Alarm | 23Vdc@load<50% 22Vdc@load≥50% |
46Vdc@load<50%; 44Vdc@load≥50% | ||
Battery Low Voltage Re-connection | 23.5Vdc@load<50% 23Vdc@load≥50% |
47Vdc@load<50%; 46Vdc@load≥50% | ||
DC Low Voltage Disconnection | 21.5Vdc@load<50% 21Vdc@load≥50% |
43Vdc@load<50%; 42Vdc@load≥50% | ||
High DC Input Alarm & Fault | 31.5Vdc±0.4V | 63Vdc±0.4V | ||
High DC Input Recovery | 31Vdc±0.4V | 62Vdc±0.4V | ||
General Specifications | ||||
Operating Temperature | 0 ℃ ~ 40 ℃ | |||
Storage Temperature | -15 ℃ ~ 60 ℃ | |||
Net Weight (KG) | 30.4 KG | 30 KG | 38.1 KG | 55.9 KG |
Gross Weight (KG) | 33.5 KG | 32.8KG | 41.6 KG | 67.2 KG |
Product Dimension (mm) | 440*391*195 mm | 494*420*195 mm | 580*420*195 mm | |
Package Dimension (mm) | 552*408*290 mm | 607*540*290 mm | 690*480*335 mm |