Product Advantages:
· Support Wi-Fi for mobile monitoring.
· 48V low voltage battery, transformer isolation topology.
· Max. charging/discharging current of 100A.
· AC couple to retrofit existing solar system.
· Support storing energy from diesel generator.
· Power supply can be switched automatically.
· Long warranty period:10 years.
· Convenient RS232/RS485 Communication.
· IP65 Protection level.
Data Sheet
Model
IVGM4648-LS
IVGM5048-LS
Battery Input Data
Battery Voltage Range
40V~60V
Max. charging and discharging current
100A/100A
Max. charging and discharging power
4600W
4600W
Battery type
Li-Ion /Lead-acid
DC Input Data (PV side)
Max. recommended PV power
6000W
6500W
Max. PV voltage
550V
Start voltage
130V
PV voltage range
90V~550V
MPPT voltage range
100V~500V
MPPT Voltage Range for Full Load
200V~500V
200V~500V
Nominal voltage
360V
Max. input current
15A/15A
Max. shorted curent
18A/18A
Number of MPP trackers / strings per MPP tracker
2/1
Grid Data
Nominal Input Voltage
230Vac
Input Voltage Range
184~264.5Vac*
Nominal grid frequency
50/60Hz*
Max. input current
40A
Max. Charge Current
100A
Max. AC output power
4600W
5000W
AC Output Rated Current
20A
24.5A
Max. output current
25A
>0.99
Max. Continuous AC Pass through
30A
Power factor
>0.99
Displacement power factor
0.8leading…0.8lagging
THDI
<3%
AC Output Data(Back Up)
Rated output power
4600VA/4600W
5000VA/5000W
Max. Output current
30A
Rated AC output voltage
230Vac
Rated AC output frequency
50/60Hz
Efficiency
Max. efficiency
97.60%
Euro efficiency
97.00%
MPPT efficiency
99.90%
General Data
Operating temperature range
–25°C~60°C,>45℃ Derating
Protection degree
IP65
Relative humidity
100%
Cooling concept
Nature
Altitude
2000m
Communication
RS232/RS485
BMS Communication
CAN/RS485
Monitor module
WiFi/GPRS
Display
LCD+LED
Installation Style
Wall-mounted
Warranty
10 years
Grid Regulation
VDE-AR-N 4105; G99/1; EN50549-1; CEI 0-21; AS 4777.2; NRS 097-2-1;
Safety Regulation
IEC 62109-1/2, IEC 62040-1
EMC
EN61000-6-1, EN61000-6-3
Net Weight(KG)
34.2KG
Gross Weight(KG)
38.6KG
Product Dimension(MM)
493*530*203
Package Dimension(MM)
632*585*315
Product Details
RFQ
1.How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
2.How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the size of the power inverter.
3.How to calculate the load of working hours requires configuration of the battery size?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)